Refurbished CISCO886-SEC-K9 Technical Specifications
Cisco Router 886 ADSL2/2+ AnnexB Sec Router
Product Number: CISCO886-SEC-K9
Description: Cisco 886 ADSL2/2+ Annex B Security Router with Advanced IP Services
Default and maximum flash memory: 128 MB
WAN
● Fast Ethernet
● Multimode VDSL2 and ADSl2/2+ over ISDN with ISDN backup
● Multimode VDSL2 and ADSl2/2+ over basic telephone service
● ADSL2/2+ over ISDN with ISDN backup
● ADSL2/2+ over basic telephone service with ISDN backup
● VDSL2 over basic telephone service with ISDN backup
● Multimode G.SHDSL (2- and 4-wire support) with ISDN backup
● Fast Ethernet and 3G WAN for Code Division Multiple Access (CDMA) and high-speed downlink packet access (HSDPA)
LAN switch
Managed 4-port 10/100BASE-T with autosensing Media Device In/Media Device Cross-Over (MDI/MDX) for auto crossover
Standard 802.11g/n access point based on IEEE 802.11n draft 2.0 standard
Optional on all models
Console or auxiliary port:RJ-45
One USB 1.1 port for advanced security features such as security tokens or USB flash memory
● One USB 1.1 port on Cisco 880 Series Routers
● USB devices supported:
● USB eTokens
● USB flash memory
External power supply
Universal 100 to 240 VAC input; 60W, 12 VDC output
Physical dimensions and weight
Product dimensions, nonwireless models (H x W x D):
● 1.9 x 12.8 x 9.8 in. (48 x 325 x 249 mm) (includes rubber feet)
● 1.75 x 12.8 x 9.8 in. (44 x 325 x 249 mm) (without rubber feet)
● Weight: 5.5 lb (2.5 kg) maximum
Power
Product power specifications:
● AC input voltage: 100 to 240 VAC
● Frequency: 50 to 60 Hz
● Maximum output power: 60W
● Output voltages: 12 VDC
Optional internal PoE with external adapter:
● Maximum output power: 80W
● External output voltage: 48 VDC
Approvals and compliance
Emissions:
● 47 CFR Part 15: 2006
● CISPR22: 2005
● EN300386: V1.3.3: 2005
● EN55022: 2006
● EN61000-3-2: 2000 [Inc amd 1 and 2]
● EN61000-3-3: 1995 [+ amd 1: 2001]
● ICES-003 Issue 4: 2004
● KN 22: 2005
● VCCI: V-3/2006.04
Immunity:
● CISPR24: 1997 [+ amd 1 and 2]
● EN300386: V1.3.3: 2005
● EN50082-1: 1992
● EN50082-1: 1997
● EN55024: 1998 [+ amd 1 and 2]
● EN61000-6-1: 2001
The following are supported on teleworker models:
● AS/NRZ 3548: 1992 Class B
● CFR 47 Part 15 Class B
● EN60555-2 Class B
● EN55022 Class B
● ICES-003, Issue 2, Class B, April 1997S
Environmental operating range
● Nonoperating temperature: -4 to 149°F (-20 to 65°C)
● Nonoperating humidity: 5 to 95% relative humidity (noncondensing)
● Nonoperating altitude: 0 to 15,000 ft (0 to 4570m)
● Operating temperature
● At sea level: 32 to 104°F (0 to 40°C)
● Up 10,000 ft: 32 to 77°F (0 to 25°C)
● Derating 2.7°F/10,000 ft (1.5°C/1,000 ft)
● Operating humidity: 10 to 85% relative humidity (noncondensing)
● Operating altitude: 0 to 10,000 ft (0 to 3000m)
Reviews